๐ง Product Overview
The ABB 2.408.140.21 is a legacy PLC control board identified with the Schiele SPS-600 automation platform. It is commonly described as an SPS-600 CPU module and serves as the central processing unit within the controller architecture.
This board is intended for replacement and maintenance of existing legacy SPS-600 installations. Because older SPS-600 systems can use different hardware configurations and revisions, the complete part number, board markings, connectors, and host rack should be checked before installation.
โ๏ธ Key Features
- ๐น Manufacturer: ABB / ASEA Brown Boveri / Entrelec
- ๐น Part Number: 2.408.140.21
- ๐น Product Type: PLC CPU / control board
- ๐น Associated Platform: Schiele SPS-600
- ๐น Function: Central processing and PLC control
- ๐น Designed for legacy industrial automation systems
- ๐น Board-level replacement for compatible SPS-600 installations
- ๐น Suitable for maintenance and spare-parts inventory
- ๐น Exact revision and system configuration should be verified before replacement
๐ Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | ABB / ASEA Brown Boveri / Entrelec |
| Model / Part Number | 2.408.140.21 |
| Product Name | SPS-600 CPU Control Board |
| Product Type | PLC CPU Module / Control Board |
| Controller Family | Schiele SPS-600 |
| System Function | Central Processing / PLC Control |
| Application | Industrial Automation |
| Communication / I/O | Configuration dependent |
| Dimensions | Approx. 203 ร 127 ร 25 mm; verify actual revision |
| Weight | Approx. 0.1 kg; verify actual unit |
| Condition | As supplied; verify listing condition |
๐ง CPU and Control Function
The 2.408.140.21 serves as the processing element of the SPS-600 PLC architecture. In an installed controller, the CPU coordinates the execution of the control program and exchanges data with the connected I/O and system modules.
For replacement work, the CPU board should be considered part of a complete controller configuration rather than an independent general-purpose PLC module. Rack type, power supply, I/O modules, communication modules, program configuration, and hardware revision can all affect compatibility.
๐ System Integration
When replacing an existing 2.408.140.21:
- ๐น Confirm the original part number before removal.
- ๐น Compare PCB revision and identification labels.
- ๐น Check the mating rack and backplane connections.
- ๐น Verify the associated SPS-600 power supply.
- ๐น Record I/O and communication module positions.
- ๐น Preserve the original program/configuration where applicable.
- ๐น Check all connectors for oxidation, bent contacts, or mechanical damage.
- ๐น Perform controller diagnostics after installation.
The replacement should match the original SPS-600 hardware configuration as closely as possible.
๐ญ Typical Applications
The SPS-600 CPU board may be found in legacy industrial automation equipment such as:
- Factory automation systems
- Machine control equipment
- Production machinery
- Process control systems
- Industrial material-handling equipment
- Legacy PLC installations
- OEM automation cabinets
- Industrial equipment requiring SPS-600 replacement parts
๐ ๏ธ Installation & Maintenance
- Shut down the controlled machine according to the approved operating procedure.
- Isolate the PLC power supply before removing the CPU board.
- Allow the cabinet to discharge and verify that hazardous voltage is absent.
- Record cable and connector positions.
- Remove the original CPU board using appropriate ESD precautions.
- Compare the replacement board’s part number and revision with the removed unit.
- Install the board into the correct SPS-600 rack position.
- Reconnect all associated wiring and modules.
- Restore power and check controller status indications.
- Verify PLC operation, I/O communication, and machine sequence before returning the equipment to service.
๐ Troubleshooting
The PLC does not start after CPU replacement
Check the rack power supply, backplane connection, CPU seating, and board revision. Confirm that the replacement CPU is suitable for the SPS-600 configuration.
I/O modules are not detected
Inspect the backplane and module connections. Check whether the I/O arrangement matches the original controller configuration.
The controller starts but the machine does not operate correctly
Verify the PLC program/configuration, I/O addressing, communication settings, and connected field devices. A CPU replacement may require restoration of the correct application configuration.
Intermittent CPU faults occur
Inspect the board for contamination, corrosion, loose connectors, damaged components, or signs of thermal stress. Also check cabinet power quality and grounding.
๐ง Maintenance Checklist
- Inspect PCB surfaces for dust and contamination.
- Check connectors and backplane contacts.
- Look for discoloration or overheated components.
- Verify cabinet temperature and ventilation.
- Check the stability of the PLC power supply.
- Maintain a backup of the applicable control program.
- Record the installed CPU revision and system configuration.
- Keep a tested spare CPU available for legacy equipment.
โ Frequently Asked Questions
What is ABB 2.408.140.21?
It is a legacy PLC CPU/control board associated with the Schiele SPS-600 automation platform.
Is 2.408.140.21 an I/O module?
No. It is identified as a CPU module and functions as a central processing unit within the SPS-600 controller.
What system uses this board?
The part is associated with the Schiele SPS-600 PLC system.
Can it replace any SPS-600 CPU?
Not automatically. The complete part number, revision, rack, backplane, power supply, and system configuration should be checked before replacement.
Does the CPU contain the machine program?
Program storage and configuration depend on the specific SPS-600 system architecture. Always verify and back up the original controller configuration before service work.
What should I provide when ordering?
Provide the complete part number 2.408.140.21, photos of the board label if available, and the model information of the existing SPS-600 controller.
Is this part suitable for legacy equipment maintenance?
Yes. It is particularly useful as a replacement or spare for compatible SPS-600 installations.
๐ฆ Recommended Related ABB / Entrelec Models
- ABB 2.408.051.00 | SPS-600 PLC Rack
- ABB 2.408.180.00 | SPS-600 Digital Input Module
- ABB 2.423.430.00 | Digital Input Module
- ABB 2.423.476.00 | Processor / I/O Bus Master Module
- ABB 2.423.436.00 | Analog Input Module
- ABB 2.408.381.00 | Analog Input Board
- ABB 2.407.410.06 | Logic Controller
- ABB 2.407.401.23 | SPS-400 Controller Module
- ABB 2.423.424.00 | RS-485 Interface Module
- ABB 2.423.425.00 | RS-485 Processor Module
๐ Spare Parts Recommendation
For legacy SPS-600 installations, maintaining a tested spare CPU can reduce downtime when controller faults occur. Before purchasing, match 2.408.140.21 against the existing CPU label, hardware revision, rack configuration, and connector arrangement to minimize compatibility risk.