Product Overview
The TELEMECANIQUE ATV71HC11N4 is an Altivar 71 high-power variable speed drive designed for three-phase motor control in demanding industrial applications. It is rated for 110 kW / 150 HP at 380–480 VAC and incorporates an integrated EMC filter and graphic terminal. Schneider Electric identifies it as an Altivar 71 variable speed drive for complex, high-power machines.
The drive supports multiple motor-control strategies, including sensorless flux vector control and flux vector control with a sensor, making it suitable for machinery requiring controlled motor speed, torque, acceleration, and deceleration.
This model is now a legacy/discontinued product. Schneider Electric has published newer Altivar Process ATV930 replacement options, so the exact ATV71HC11N4 part number remains important when maintaining an existing installation.
Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | TELEMECANIQUE / Schneider Electric |
| Model | ATV71HC11N4 |
| Product Family | Altivar 71 |
| Product Type | Variable Speed Drive / AC Drive |
| Motor Rating | 110 kW / 150 HP |
| Input Voltage | 380–480 VAC, 3-phase |
| Line Current | 202 A at 380 V / 163 A at 480 V |
| Nominal Output Current | 215 A |
| Output Frequency | 0.1–500 Hz |
| EMC / Construction | Integrated EMC filter, heatsink, reinforced version |
The published data also specifies an apparent power of 133 kVA at 380 V, a prospective line short-circuit current of 35 kA, and maximum motor-cable lengths of 100 m with shielded cable or 200 m with unshielded cable under the specified conditions.
Key Features
- 110 kW / 150 HP high-power AC drive
- Three-phase 380–480 VAC supply
- Altivar 71 drive platform
- Integrated EMC filter
- Graphic terminal configuration
- Reinforced high-power construction
- Nominal output current of 215 A
- Output frequency range of 0.1–500 Hz
- Adjustable switching frequency from 2.5–8 kHz, with derating as applicable
- Sensorless and sensor-based flux vector control
- Designed for complex, high-power machinery
Motor Control & System Integration
The ATV71HC11N4 can be integrated into industrial motor-control systems where precise variable-speed operation is required. Its control functions support:
- Sensorless flux vector control
- Flux vector control with speed feedback
- Voltage/frequency control
- Energy-adaptation control for certain unbalanced-load applications
When replacing an existing ATV71 drive, verify the original motor nameplate, motor-control mode, acceleration/deceleration parameters, command source, reference source, braking arrangement, communication options, and installed configuration.
For high-power installations, the upstream protection, motor cable, grounding, EMC arrangement, cooling, and cabinet ventilation must be evaluated as part of the complete drive system.
Industrial Applications
The ATV71HC11N4 is suitable for compatible high-power machinery such as:
- Pumps and fans
- Conveyors
- Compressors
- Material-handling equipment
- Industrial processing machinery
- Large machine tools
- Hoisting and lifting equipment
- Production-line machinery
- Marine and heavy industrial motor systems
The ATV71 range was specifically positioned for complex, high-power machines.
Installation & Maintenance
1. Verify the Drive Rating
Confirm that the replacement is specifically ATV71HC11N4 and that the motor/application requirements correspond to the 110 kW, 380–480 V rating.
2. Inspect the Power Section
Before installation, inspect terminals, busbar connections, cooling surfaces, fans, capacitors, and visible power components for damage or contamination.
3. Verify Motor Data
Enter or confirm the motor nameplate parameters required by the existing application. Incorrect motor parameters can cause poor regulation, overcurrent trips, or motor overheating.
4. Check Cable and Grounding
Verify motor cable sizing, shielding, grounding, cabinet bonding, and cable routing according to the applicable installation documentation.
5. Check Control Configuration
Confirm the command source, speed reference, I/O assignments, ramp parameters, motor-control mode, fault handling, and communication settings.
6. Commission at Low Risk
After power-up, perform controlled testing before returning the machinery to full production load.
Troubleshooting
Drive trips on overcurrent:
Check motor parameters, mechanical load, acceleration time, motor wiring, insulation condition, and current limits.
Drive trips during acceleration:
Review acceleration ramps and motor-control settings. Excessive mechanical load or an incorrect motor configuration can also cause high current.
Motor speed is unstable:
Check motor data, feedback configuration if used, speed-reference scaling, control mode, and mechanical load.
Drive overheats:
Inspect cooling fans, heatsink contamination, cabinet ventilation, ambient temperature, and installation clearance.
Communication or remote control does not work:
Check the installed communication option, control-source configuration, network wiring, addressing, and parameter settings.
Replacement drive does not behave like the original:
Compare the complete parameter set and installed options. A drive with the same basic power rating is not automatically a configuration-equivalent replacement.
First-Operation Checklist
☐ Confirm ATV71HC11N4 model number
☐ Confirm 380–480 VAC three-phase supply
☐ Confirm motor rating and nameplate data
☐ Inspect power terminals and cooling system
☐ Verify grounding and EMC arrangement
☐ Check motor cable and insulation
☐ Confirm command and speed-reference sources
☐ Verify motor-control parameters
☐ Check acceleration/deceleration settings
☐ Perform unloaded or controlled-load testing
☐ Review alarms and fault history
☐ Complete full-load commissioning only after successful preliminary testing
FAQ
What is the ATV71HC11N4?
It is a Telemecanique/Schneider Electric Altivar 71 variable speed drive rated at 110 kW / 150 HP for three-phase 380–480 VAC applications.
What motor power is this drive designed for?
The published rating is 110 kW / 150 HP at 380–480 VAC, three-phase.
What is the nominal output current?
The published nominal output current is 215 A under the specified 2.5 kHz operating conditions.
Does it have an EMC filter?
Yes. The ATV71HC11N4 has an integrated EMC filter.
Is the ATV71HC11N4 still manufactured?
No. Schneider Electric lists the model as discontinued/end-of-commercialization, with after-sales support continuing for a defined service period.
What is the recommended modernization direction?
Schneider Electric lists Altivar Process ATV930 models as replacement options, including ATV930C11N4C and ATV930C13N4 depending on the required configuration. A replacement must be engineered against the original application’s electrical and mechanical requirements rather than selected solely by kW rating.
Can an ATV930 simply replace this ATV71?
Not as a direct plug-and-play assumption. Control architecture, dimensions, wiring, options, braking requirements, parameters, communication, and application functions must be reviewed before modernization.
Related Altivar Models
- Telemecanique ATV71HC11N4
- Altivar 71 ATV71HD75M3X
- Altivar 71 ATV71HC11N4D
- Altivar 71 ATV71 series high-power drives
- Altivar 71 control terminals
- Altivar 71 communication options
- Altivar 71 braking components
- Altivar Process ATV930C11N4C
- Altivar Process ATV930C13N4
- Schneider Electric Altivar 900 Series
The related models should not be considered automatic electrical replacements. Exact compatibility depends on motor rating, supply, enclosure, braking, control architecture, installed options, and application requirements.
Spare-Parts & Lifecycle Planning
Because ATV71HC11N4 is a discontinued high-power drive, maintaining a verified spare can be valuable for legacy production equipment. Schneider Electric currently identifies an Altivar Process ATV930 family as the modernization direction for this model.
For lifecycle management:
- Keep at least one verified spare for critical production equipment.
- Record the complete model and option configuration.
- Preserve the original parameter backup.
- Record motor nameplate and application settings.
- Inspect stored drives periodically.
- Use ABC classification for critical drive inventory.
- Maintain buffer stock where downtime costs are high.
- Evaluate an engineering-approved ATV930 modernization before the existing ATV71 reaches the end of service.
For a replacement purchase, the most important identification is TELEMECANIQUE ATV71HC11N4, not simply “110 kW Altivar 71,” because different ATV71 variants can have different electrical and mechanical configurations.