🔹 Product Overview
The GE SENSING MTS6-3-6-1-0 is a Moisture Target Series 6 single-channel hygrometer designed for real-time moisture measurement in gases and compressed-air applications.
The MTS6 uses a microprocessor-based electronics platform and is compatible with GE/Panametrics M Series aluminum-oxide moisture probes and VeriDri moisture transmitters. It provides local LCD indication, configurable analog output, measurement alarm relays, fault monitoring, and onboard data logging.
This instrument is well suited for OEM equipment, industrial process monitoring, air and gas dryers, and maintenance or replacement of existing Moisture Target Series 6 installations.
⚙️ Key Features
- GE SENSING Moisture Target Series 6 platform
- Model MTS6-3-6-1-0
- Single-channel moisture measurement
- Microprocessor-based electronics
- LCD display and front-panel keypad
- Compatible with M Series moisture probes
- Compatible with VeriDri moisture transmitters
- Isolated analog voltage or current output
- Two measurement alarm relays
- Fail-safe fault alarm relay
- MicroSD data logging capability
- Panel-mount installation
- Suitable for OEM and industrial process applications
📡 Measurement & Signal Integration
The MTS6 measures gas moisture through a compatible moisture probe or transmitter and converts the measured information into a readable process value.
The instrument can provide dew/frost point information and configurable analog output for connection to a PLC, DCS, recorder, supervisory controller, or other process-monitoring equipment. The standard output options include 0–2 V, 0–20 mA, and 4–20 mA, depending on configuration.
A typical process arrangement is:
Process Gas → M Series / VeriDri Moisture Sensor → MTS6 Electronics → Analog Output / Alarm → PLC, DCS or Monitoring System
The MTS6 also provides alarm and fault relay functions for integration with equipment protection or process-control logic.
🏭 Typical Applications
- Compressed-air moisture monitoring
- Regenerative desiccant air dryers
- Industrial gas dryers
- Medical air dryer systems
- Plastic drying equipment
- Glove box moisture monitoring
- OEM process equipment
- Industrial gas-process monitoring
- Moisture measurement and dew-point control
- Existing MTS6 system replacement
The unit is especially useful where real-time moisture information is required for closed-loop process control or dryer management.
📋 Technical Datasheet
| Parameter | Specification |
|---|---|
| Brand | GE SENSING |
| Model | MTS6-3-6-1-0 |
| Product Series | Moisture Target Series 6 |
| Product Name | Moisture Target Series 6 Hygrometer |
| Product Type | Single-Channel Gas Moisture Analyzer |
| Measurement Technology | Thin-Film Aluminum Oxide Moisture Sensor |
| Probe Compatibility | M Series Moisture Probes / VeriDri Transmitters |
| Analog Output | 0–2 V, 0–20 mA, or 4–20 mA, configuration dependent |
| Alarm / Data Logging | Two measurement alarm relays, fault relay, MicroSD logging |
| Power Supply | 100–240 VAC or 24 VDC, configuration dependent |
🔧 Installation & Commissioning
- Verify the complete model number MTS6-3-6-1-0 and confirm the intended power configuration.
- Confirm that the connected moisture probe or VeriDri transmitter is compatible with the MTS6.
- Install the electronics unit in the appropriate panel location and provide adequate clearance for wiring and servicing.
- Connect the moisture probe using the correct cable and terminal arrangement.
- Connect the selected analog output to the PLC, DCS, recorder, or monitoring device.
- Connect the alarm and fault relay circuits according to the system control drawing.
- Apply the specified power supply and observe the startup display.
- Verify the probe type, calibration information, measurement units, and output configuration.
- Check the analog output against the receiving control system.
- Test the alarm and fault functions before placing the measurement loop into normal operation.
The MTS6 installation procedure includes mounting the electronics, installing the probe, wiring the power supply, and connecting probe and alarm circuits.
🔍 Troubleshooting
No moisture reading:
Check probe wiring, probe type selection, sensor condition, connector seating, and calibration information.
Incorrect dew-point value:
Verify the selected probe, calibration data, measurement units, and process sampling conditions.
Analog output does not match the displayed value:
Check the selected output type, zero/span configuration, receiving-system scaling, and cable connections.
Alarm remains active:
Review the alarm setpoints, alarm type, process value, and fail-safe configuration.
Intermittent measurement:
Inspect the probe cable, connectors, grounding, process sample system, and possible electrical interference.
No communication with the monitoring system:
The MTS6 primarily provides local measurement, analog output, relay outputs, and data logging. Verify that the receiving PLC/DCS is correctly scaled for the selected analog signal.
🧰 Maintenance Recommendations
- Keep the moisture probe clean and properly installed.
- Periodically verify probe calibration against the required calibration standard.
- Inspect probe cables and connectors for mechanical damage or contamination.
- Check analog output scaling during scheduled maintenance.
- Test alarm and fault relay operation periodically.
- Keep a record of probe serial numbers and calibration information.
- Protect the electronics from excessive moisture, vibration, and contamination.
- Use compatible replacement probes when servicing the measurement system.
The MTS6 supports calibration-data entry and provides menu functions for checking probe information, wiring, status, and software information.
♻️ Replacement Considerations
When replacing an existing MTS6, the complete ordering code should be compared rather than selecting a unit solely by the “MTS6” family name.
Check:
- MTS6 model and ordering code
- Power-supply configuration
- Probe type
- Probe serial number
- Calibration range
- Analog output configuration
- Alarm configuration
- Existing panel cutout
- Process sampling arrangement
- PLC/DCS input scaling
The MTS6 family supports different power and probe configurations, so matching the installed system configuration is important for a successful replacement.
❓ Frequently Asked Questions
What is the GE SENSING MTS6-3-6-1-0?
It is a Moisture Target Series 6 single-channel hygrometer for measuring moisture content in gases.
What type of sensor does the MTS6 use?
The MTS6 is designed to work with thin-film aluminum oxide moisture sensors, including compatible M Series probes and VeriDri transmitters.
Can the MTS6 measure dew point?
Yes. The system can display dew/frost point temperature according to the installed sensor and configured measurement range.
Does the MTS6 have an analog output?
Yes. Supported configurations include voltage and current outputs such as 0–2 V, 0–20 mA, and 4–20 mA.
Does it have alarm outputs?
Yes. The MTS6 provides two measurement alarm relays and a fault alarm relay.
Can measurement data be recorded?
Yes. The MTS6 includes onboard MicroSD data-logging capability.
Can it replace an older MTS6?
Potentially, provided the model configuration, power supply, probe, output configuration, and application requirements are compatible.
🔩 10 Recommended Related GE SENSING / Moisture Measurement Models
- GE SENSING MTS6 Moisture Target Series 6
- GE SENSING MTS5 Moisture Target Series 5
- GE SENSING M Series Moisture Probe
- GE SENSING M1 Moisture Probe
- GE SENSING M2 Moisture Probe
- GE SENSING VeriDri Moisture Transmitter
- GE SENSING Moisture Monitor Series
- GE SENSING Dew Point Measurement Systems
- Panametrics Moisture Measurement Systems
- Panametrics Industrial Moisture Analyzers
✅ Product Summary
The GE SENSING MTS6-3-6-1-0 Moisture Target Series 6 Hygrometer is a compact single-channel moisture measurement instrument for industrial gas and compressed-air applications. Its combination of compatible moisture probes, configurable analog output, alarm relays, LCD indication, and MicroSD logging makes it suitable for OEM equipment and replacement of existing moisture-monitoring installations.
For replacement projects, verify the complete ordering code, power configuration, probe type, calibration information, output configuration, and existing control-system wiring before installation.