🔹 Product Description
The GE Panametrics DF868-2-14-10000-0 is a DigitalFlow ultrasonic liquid flowmeter designed for accurate, non-intrusive measurement of liquid flow in industrial piping systems.
The DF868 uses patented Correlation Transit-Time™ ultrasonic technology and can measure flow from outside the pipe when equipped with compatible clamp-on transducers. It can also support wetted transducers for applications requiring an alternative measurement arrangement. The system is suitable for many acoustically conductive liquids, including water, glycol solutions, hydrocarbons, petroleum products, oils, fuels, solvents, and chemicals.
The DF868-2 configuration indicates a two-channel platform, which can be used for two pipes or two-path averaging depending on the installed configuration. The instrument also supports volumetric flow, totalized flow, and flow velocity measurement, making it suitable for process monitoring, flow verification, energy management, commissioning, and maintenance applications.
⚙️ Key Features
- GE Panametrics DigitalFlow DF868 platform
- Two-channel ultrasonic flowmeter configuration
- Correlation Transit-Time™ measurement technology
- Non-intrusive clamp-on measurement capability
- Compatible with wetted ultrasonic transducers
- Measures flow velocity, volumetric flow, and totalized flow
- Bidirectional flow measurement
- Up to 400:1 overall rangeability
- Two independent backlit LCD graphic displays
- Built-in data logging capability
- Two isolated 0/4–20 mA outputs
- Suitable for a wide range of industrial liquids
📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | GE Panametrics |
| Model | DF868-2-14-10000-0 |
| Series | DigitalFlow DF868 |
| Product Name | Multipurpose Ultrasonic Liquid Flowmeter |
| Measurement Technology | Correlation Transit-Time™ Ultrasonic |
| Channel Configuration | Two Channel |
| Flow Range | −40 to +40 ft/s (−12.2 to +12.2 m/s) |
| Pipe Size | 0.5–300 in with clamp-on transducers; configuration dependent |
| Dimensions | Approx. 362 × 290 × 130 mm |
| Weight | Approx. 5 kg |
| Power Consumption | 20 W maximum |
🔧 Typical Applications
- Water and wastewater flow measurement
- Hot and chilled water systems
- Water/glycol circulation
- Petroleum and refined hydrocarbon measurement
- Crude oil and fuel oil systems
- Lubricating oil measurement
- Chemical process lines
- Solvent measurement
- Pump and piping diagnostics
- Flowmeter verification and commissioning
The DF868 can work with all metals and most plastics, although pipe construction, lining, corrosion, wall thickness, liquid condition, and transducer selection affect measurement performance.
🔌 System Integration
The DF868 can provide measured flow information to external control, monitoring, or data-acquisition systems through its analog outputs. Standard specifications include two isolated 0/4–20 mA outputs, while additional input/output functions can depend on installed option cards. The DF868 platform can accommodate multiple option cards for expanded functionality.
For replacement or retrofit applications, verify the complete DF868-2-14-10000-0 configuration against the existing installation. Particular attention should be given to ultrasonic transducer type, frequency, cable length, pipe diameter, pipe-wall thickness, liquid characteristics, power supply, option cards, analog I/O, and programmed site parameters.
❓ Common Questions & Answers
Q1: What is the GE Panametrics DF868 used for?
A1: It is an ultrasonic flowmeter designed to measure liquid flow velocity, volumetric flow, and totalized flow.
Q2: Is the DF868 a clamp-on flowmeter?
A2: Yes. The DF868 supports clamp-on ultrasonic transducers for non-intrusive flow measurement. Wetted transducers are also supported.
Q3: What does the “-2” in DF868-2 indicate?
A3: The DF868-2 configuration represents a two-channel version, allowing applications such as measurement on two pipes or two-path averaging.
Q4: What is the maximum flow velocity range?
A4: The specified bidirectional transit-time range is approximately −40 to +40 ft/s, or −12.2 to +12.2 m/s.
Q5: What pipe sizes can the DF868 handle?
A5: With clamp-on transducers, the specified range is approximately 0.5 to 300 inches and larger, depending on the transducer and application.
Q6: What liquids can it measure?
A6: It can measure many acoustically conductive liquids, including clean liquids and certain liquids containing entrained solids or gas bubbles.
Q7: What outputs are available?
A7: Standard specifications include two isolated 0/4–20 mA outputs. Additional I/O can depend on installed option cards.
Q8: Can the DF868 measure bidirectional flow?
A8: Yes. The specified transit-time measurement range extends from negative to positive flow velocity.
Q9: What should be checked when replacing an existing DF868?
A9: Verify the complete model/configuration, transducers, cables, power supply, option cards, pipe parameters, programmed site data, and required output configuration.
Q10: Does the flowmeter include transducers?
A10: The transducers are configuration-dependent. For a used unit, confirm the actual contents of the package and the transducer models shown in the listing before purchase.
⭐ Recommended GE Panametrics Models
- GE Panametrics DF868
- GE Panametrics DF868-1
- GE Panametrics DF868-2
- GE Panametrics PT878
- GE Panametrics PT900
- GE Panametrics AT868
- GE Panametrics AquaTrans AT600
- GE Panametrics TransPort PT878
- GE Panametrics DigitalFlow GF868
- GE Panametrics DigitalFlow GS868