Product Description
The Woodward easYgen-3400-5/P2, part number 8440-2078, is a genset control and synchronization controller from the easYgen-3000 Series. It is designed for generator-set control, synchronization, load sharing, breaker control, monitoring, and protection in complex power-generation applications.
Woodward identifies 8440-2078 as the easYgen-3400-5/P2 version. The P2 package extends the easYgen-3400 platform with additional digital and analog I/O compared with the P1 configuration.
The 5/P2 configuration uses 5 A current-transformer inputs and is intended for applications requiring expanded control and monitoring capabilities. Woodward documentation also identifies the easYgen-3400 family for complex breaker applications.
Key Features
- Woodward easYgen-3400-5/P2 controller
- Part number 8440-2078
- easYgen-3000 Series
- Genset control and synchronization
- Generator paralleling and load-sharing functions
- Complex breaker control applications
- 5 A CT input configuration
- Expanded P2 I/O package
- Engine and generator monitoring
- Configurable digital inputs and outputs
- Analog input and output functions
- CAN communication
- RS-485 Modbus RTU
- Ethernet communication depending on configuration
- Suitable for individual gensets and multi-generator systems
Technical Data
| Parameter | Specification |
|---|---|
| Brand | Woodward |
| Model | easYgen-3400-5/P2 |
| Part Number | 8440-2078 |
| Series | easYgen-3000 |
| Product Type | Genset Control & Synchronization Controller |
| Package | P2 |
| CT Input Rating | 5 A |
| Power Supply | 12/24 VDC |
| Digital Inputs | Configuration dependent / expanded P2 I/O |
| Digital Outputs | Configuration dependent / expanded P2 I/O |
| Analog I/O | Expanded P2 configuration |
| Communication | CAN, RS-485, Ethernet depending configuration |
| Application | Generator Control, Synchronization & Paralleling |
| Dimensions | Configuration dependent |
| Weight | Configuration dependent |
| Installation | Control-panel / genset application |
Woodward’s product documentation identifies 8440-2078 as the 5 A P2 version and lists the easYgen-3400/3500 P1/P2 family under product specification 37523 and technical manual 37528.
P2 Package Functions
Compared with the P1 configuration, the P2 version adds expanded I/O capabilities. Documentation for the easYgen-3400 P2 identifies additional digital outputs and monitoring inputs together with analog I/O for more complex generator-control applications.
Typical functions include:
- Generator voltage and frequency monitoring
- Generator current and power measurement
- Engine start/stop control
- Generator breaker control
- Utility/mains breaker control
- Synchronization
- Active and reactive load sharing
- Generator protection
- Alarm and shutdown monitoring
- Configurable control logic
- Communication with external control systems
Applications
The easYgen-3400-5/P2 can be applied to:
- Standby generator systems
- Prime-power generator sets
- Multiple-generator paralleling systems
- Generator synchronization systems
- CHP and distributed-generation systems
- Industrial power plants
- Utility/generator transfer applications
- Complex breaker-control systems
- Marine and industrial generator applications where the applicable configuration is supported
Communication & Integration
The controller can be integrated into generator-control systems using its available communication interfaces. Depending on the exact hardware and configuration, interfaces include CAN/CANopen/J1939, RS-485 Modbus RTU, and Ethernet-based communication.
For replacement applications, verify:
- Exact part number 8440-2078.
- easYgen-3400 rather than easYgen-3500.
- 5 A CT input configuration.
- P2 package.
- Generator and mains voltage configuration.
- CT/PT ratios.
- Breaker-control architecture.
- CAN/J1939 or CANopen requirements.
- Modbus/Ethernet communication configuration.
- Firmware and parameter/settings compatibility.
Woodward documentation notes that complete settings files apply across the applicable part numbers, while partial settings are revision-specific; therefore, firmware/revision should be checked before transferring configuration data.
FAQ
What is Woodward 8440-2078?
It is the part number for the easYgen-3400-5/P2 genset controller.
What does P2 mean?
P2 identifies the expanded package configuration of the easYgen-3400 platform, with additional I/O and functions compared with P1.
Is 8440-2078 a 5 A or 1 A CT version?
It is the 5 A CT-input version. Woodward lists 8440-2078 for easYgen-3400-5/P2 and 8440-2079 for the corresponding 1 A P2 version.
Is easYgen-3400-5/P2 a PLC?
It is better described as a dedicated genset control and synchronization controller rather than a general-purpose PLC.
Can 8440-2078 replace another easYgen-3400 controller?
Not automatically. The CT input rating, package level, I/O, firmware, generator configuration and breaker architecture should all be checked before replacement.
Related Woodward Models
- Woodward easYgen-3400-5/P1 — 8440-1945
- Woodward easYgen-3400-1/P1 — 8440-1956
- Woodward easYgen-3400-1/P2 — 8440-2079
- Woodward easYgen-3500-5/P1 — 8440-1934
- Woodward easYgen-3500-1/P1 — 8440-1935
- Woodward easYgen-3500-5/P2 — 8440-1936
- Woodward easYgen-3500-1/P2 — 8440-1937
- Woodward easYgen-3200-5/P2 — 8440-2052
- Woodward easYgen-3100-5/P2 — 8440-2056
- Woodward easYgen-3400XT 1A/5A P2 — 8440-2087
Product Keywords
Woodward easYgen-3400-5/P2, 8440-2078, easYgen 3400 P2, Woodward genset controller, Woodward generator controller, generator synchronization controller, generator paralleling controller, load sharing controller, genset control module, Woodward easYgen-3000