Product Description
The GE Panametrics DF868 is a fixed-installation ultrasonic liquid flowmeter designed for non-intrusive flow and energy measurement. It uses Correlation Transit-Time™ digital signal processing and can measure liquids from outside the pipe when used with compatible clamp-on transducers.
The DF868 is suitable for a broad range of industrial liquid applications, including water and wastewater, hot or chilled water, water/glycol solutions, hydrocarbons, petroleum products, lubricating oils, diesel and fuel oils, solvents, and chemicals.
The specified unit is marked DF868-2-14-10000-0. Because DF868 systems can be configured with different channel, power, transducer and output options, the complete model code and existing equipment configuration should be matched before installation.
Key Features
- Fixed-installation ultrasonic liquid flowmeter
- Non-intrusive clamp-on flow measurement
- Correlation Transit-Time™ measurement technology
- Single- or two-channel configurations available
- Measures volumetric flow, totalized flow and flow velocity
- Large backlit LCD display
- Two isolated 0/4–20 mA outputs in the standard configuration
- Suitable for clean liquids and many liquids containing entrained solids or gas bubbles
- Compatible with a wide range of pipe sizes and materials
- Energy measurement capability available depending on configuration
Technical Data
| Parameter | Specification |
|---|---|
| Brand | GE Panametrics |
| Model | DF868 |
| Configuration | DF868-2-14-10000-0 |
| Product Name | Ultrasonic Liquid Flowmeter |
| Product Type | Fixed-Installation Clamp-On Flowmeter |
| Measurement Technology | Correlation Transit-Time™ |
| Channels | 1 channel standard / 2 channels optional |
| Flow Range | -40 to +40 ft/s (-12.2 to +12.2 m/s) |
| Typical Clamp-On Accuracy | ±1–2% of reading for pipe ID >150 mm; ±2–5% for pipe ID <150 mm |
| Achievable Velocity Accuracy | ±0.5% of reading with process calibration |
| Repeatability | ±0.1–0.3% of reading |
| Pipe Size, Clamp-On | 0.5–300 in (12.7 mm–7.6 m) and larger |
| Pipe Wall Thickness | Up to 3 in (76.2 mm) |
| Standard Power | 100–130 VAC or 200–265 VAC, 50/60 Hz |
| Optional Power | 12–28 VDC ±5%, configuration dependent |
| Power Consumption | 20 W maximum |
| Operating Temperature | -20 to +55°C (-4 to +131°F) |
| Dimensions | Approx. 362 × 290 × 130 mm |
| Weight | Approx. 5 kg |
| Standard Outputs | Two isolated 0/4–20 mA outputs |
| Enclosure | Standard epoxy-coated aluminum, Type 4X/IP66 |
| Condition / Status | Refer to item-specific listing condition |
Specifications above are from Panametrics/GE DF868 documentation and describe the DF868 platform; exact options for DF868-2-14-10000-0 should be confirmed from the unit nameplate and configuration records.
Measurement & System Integration
The DF868 can measure flow velocity, volumetric flow and totalized flow. Its ultrasonic measurement principle allows flow measurement without cutting into the process pipe, making it useful for applications where process interruption or pressure loss should be avoided.
For clamp-on installations, compatible transducers are mounted externally on the pipe. Panametrics specifies support for many metal and plastic pipe materials and pipe sizes ranging from approximately 0.5 to 300 inches and larger, depending on the transducer and application.
Before replacement or commissioning, verify:
- Complete model number: DF868-2-14-10000-0
- Transducer model and frequency
- Clamp-on or wetted-transducer configuration
- One- or two-channel configuration
- Required power supply
- Pipe material and diameter
- Required output and communication options
- Existing flowmeter programming and calibration parameters
Installation Notes
The DF868 is intended for fixed industrial installation. Proper transducer positioning and pipe conditions are important to measurement accuracy. Panametrics notes that the stated accuracy specifications assume a developed flow profile, typically with approximately 10 pipe diameters of straight pipe upstream and 5 pipe diameters downstream.
When replacing an existing DF868, retain the original configuration and calibration information where applicable. The electronics model alone does not determine the correct transducer set or complete measurement setup.
FAQ
Q: What is the GE Panametrics DF868 used for?
A: It is a fixed ultrasonic liquid flowmeter for measuring liquid flow and, depending on configuration, energy flow.
Q: Is the DF868 a clamp-on flowmeter?
A: Yes. The DF868 supports non-intrusive clamp-on measurement, while compatible wetted-transducer configurations are also available.
Q: What liquids can the DF868 measure?
A: Applications include water, wastewater, hot/chilled water, water/glycol, hydrocarbons, petroleum products, oils, fuels, solvents and chemicals.
Q: What is the measurement range?
A: The documented bidirectional velocity range is -40 to +40 ft/s (-12.2 to +12.2 m/s).
Q: Does the DF868 require cutting the pipe?
A: With compatible clamp-on transducers, measurement is performed externally without pipe penetration.
Q: Does DF868-2-14-10000-0 include transducers?
A: The model code identifies a configured DF868 unit, but the supplied code alone should not be used to assume a particular transducer set. Confirm the actual package contents and nameplate configuration before ordering.
Recommended Related Panametrics Models
- Panametrics DigitalFlow DF868
- Panametrics DigitalFlow GC868
- Panametrics DigitalFlow GM868
- Panametrics DigitalFlow GS868
- Panametrics DigitalFlow XMT868i
- Panametrics DigitalFlow XGS868i
- Panametrics AquaTrans AT600
- Panametrics AquaTrans AT620
- Panametrics AquaTrans AT868
- Panametrics PanaFlow LC