1. Product Introduction
The DEIF CSQ-3 Marine 450V is a multifunction synchroscope and check synchronizing relay designed for marine generator synchronization and power management systems.
It combines synchroscope indication and automatic synchronizing supervision in one microprocessor-controlled instrument. The unit monitors generator and busbar voltage conditions, phase angle differences, and frequency differences to determine when synchronization conditions are acceptable.
The Marine version includes an additional optocoupler output for system status monitoring. This makes the CSQ-3 suitable for shipboard switchboards, generator control panels, and marine electrical power management installations.
2. Datasheet & Technical Specifications
- Manufacturer: DEIF A/S
- Model: CSQ-3
- Product Type: Multifunction Synchroscope
- Version: Marine
- Nominal Input Voltage: 450 V AC
- Input Voltage Range: 440–480 V AC
- Voltage Tolerance: +20% / -10% (above 450 V AC, +10% only)
- Operating Frequency: 40–70 Hz
- Measurement Accuracy: ±2 electrical degrees
- Display Resolution: 10 electrical degrees
- Maximum Frequency Difference: No limit
- SYNC Output: 1 SPST-NO relay contact
- Generator Input Consumption: Maximum 2 VA at nominal voltage
- Relay Contact Rating (AC1): 8 A at 250 V AC
- Relay Contact Rating (DC1): 8 A at 24 V DC
- Relay Contact Rating (AC15): 3 A at 250 V AC
- Relay Contact Rating (DC13): 3 A at 24 V DC
- Marine Status Output: Optocoupler output
- Optocoupler Maximum Rating: 40 V, 10 mA
- Operating Temperature: -25 to +70°C
- Front Protection: IP52
- Terminal Protection: IP20
- Galvanic Separation: 3,750 V AC for 1 minute
- Installation Category: III, 600 V
- Pollution Degree: 2
3. Main Features
- Multifunction synchroscope and check synchronizing relay
- Designed for marine electrical installations
- 450 V AC nominal voltage configuration
- Monitors generator and busbar synchronization conditions
- Phase angle and frequency difference supervision
- Adjustable voltage difference limits
- Adjustable phase difference limits
- Programmable synchronization relay delay
- Adjustable synchronization pulse duration
- Integrated LED status indication
- One SPST-NO synchronization relay output
- Additional optocoupler status output on Marine version
- Front-accessible programming controls
- IP52 front protection
- High-voltage galvanic isolation
4. Typical Applications
- Marine generator synchronization
- Shipboard electrical switchboards
- Diesel generator control panels
- Marine power management systems
- Generator paralleling systems
- Electrical power distribution
- Standby generator installations
- Offshore power generation
- Vessel electrical automation
- Industrial generator synchronization
5. Frequently Asked Questions
Q1: What is the DEIF CSQ-3 used for?
A: It is used to monitor generator and busbar synchronization conditions and provide a synchronizing relay output when the configured conditions are satisfied.
Q2: What does the 450V version mean?
A: It identifies the nominal voltage configuration. The specified input range is 440–480 V AC, with special tolerance limitations above 450 V AC.
Q3: What is the difference between Marine and Land versions?
A: The Marine version has an additional optocoupler output for system status monitoring and is configured for marine type approval.
Q4: Does the CSQ-3 have a relay output?
A: Yes. It provides one SPST-NO synchronization relay contact.
Q5: What is the operating frequency range?
A: The specified frequency range is 40–70 Hz.
Q6: Can the CSQ-3 be used for ship generator paralleling?
A: Yes. It is designed for synchronization supervision in marine generator and switchboard applications.
Q7: Is the CSQ-3 a complete automatic synchronizer?
A: It provides synchroscope indication and check synchronization functions. Generator speed and voltage regulation may require separate control equipment.
6. 15 Related DEIF Models and Components
The following are related DEIF synchronization, generator control, and marine power management products. They are not guaranteed direct replacements for the CSQ-3.
- DEIF CSQ-3 115V – Synchroscope
- DEIF CSQ-3 230V – Synchroscope
- DEIF CSQ-3 415V – Synchroscope
- DEIF CSQ-3 450V Marine – Synchroscope
- DEIF FAS-115DG – Automatic Synchronizer
- DEIF FAS-125DG – Automatic Synchronizer
- DEIF FAS-113DG – Automatic Synchronizer
- DEIF LSU-112DG – Load Sharing Unit
- DEIF LSU-114DG – Load Sharing Unit
- DEIF PPM 300 – Power Management System
- DEIF AGC-4 – Automatic Generator Controller
- DEIF AGC-4 Mk II – Automatic Generator Controller
- DEIF AGC 150 – Generator Controller
- DEIF GPU-3 – Generator Protection Unit
- DEIF CGC 400 – Compact Generator Controller
7. Ordering Information
Brand: DEIF
Model: CSQ-3
Voltage Version: 450V AC
Product Type: Multifunction Synchroscope
Configuration: Marine
Input Voltage Range: 440–480 V AC
Frequency Range: 40–70 Hz
Output: SPST-NO Synchronization Relay
Application: Marine Generator Synchronization
Please verify the complete model designation, voltage configuration, Marine version, and terminal condition before ordering. Confirm that the 450V version matches your generator and busbar voltage requirements.