⚙️ Product Introduction
The Woodward 8444-1019 F UMT1 Measuring Transducer is an industrial measuring and signal-conditioning component designed for use in power generation and automation control systems.
The UMT1 measuring transducer is intended to interface electrical measurement signals with compatible monitoring and control equipment. Measuring transducers play an important role in converting electrical quantities into standardized signals that can be processed by control systems, monitoring devices, and protection equipment.
Woodward equipment is widely used in generator control, turbine management, engine automation, and industrial power distribution applications.
Key Features
-
⚡ Electrical measurement and signal conversion.
-
📊 Supports integration with industrial monitoring systems.
-
🔌 Interface with compatible control and measurement equipment.
-
⚙️ Designed for industrial automation applications.
-
🏭 Suitable for power generation and electrical control environments.
-
🔧 Modular industrial equipment integration.
-
🛡️ Supports reliable measurement signal transmission.
The 8444-1019 identification should be checked against the equipment nameplate and original technical documentation to establish the exact measuring ranges and electrical configuration.
📋 Product Parameters / Datasheet
| Parameter | Description |
|---|---|
| Brand | Woodward |
| Model | UMT1 |
| Part Number | 8444-1019 |
| Revision | Rev F |
| Series | UMT 1 Measuring Transducer |
| Product Name | Electrical Measuring Transducer |
| Place of Origin | Germany (verify individual unit nameplate) |
| Product Status | Industrial measuring and monitoring equipment |
| Dimensions | 96 × 72 × 130 mm |
| Weight | Approx. 0.8 kg |
| Power Supply | 24 VDC |
| Power Consumption | Maximum 10 W |
| Voltage Input | 100 VAC nominal configuration |
| Current Input | 5 A AC |
| Analog Outputs | 6 isolated configurable outputs |
| Accuracy | Class 0.5 |
| Discontinued Status | Obsolete; no longer orderable as new according to lifecycle information |
🔍 Technical Specifications
The Woodward UMT1 uses true RMS measurement technology to monitor electrical parameters and calculate important power system values.
Measurement Functions
-
Voltage measurement.
-
Current measurement.
-
Active power measurement (kW).
-
Reactive power measurement (kvar).
-
Apparent power measurement (kVA).
-
Power factor (cos φ).
-
Active energy measurement (kWh).
-
Reactive energy measurement (kvarh).
-
Frequency measurement.
Electrical Specifications
-
Voltage Input: 100 VAC nominal configuration.
-
Current Input: 5 A AC.
-
Auxiliary Supply: 24 VDC.
-
Analog Output: Six isolated outputs.
-
Output Signal: -20 to +20 mA, 0 to 20 mA, or 4 to 20 mA.
-
Measurement Accuracy: Class 0.5.
-
Measuring Frequency: 40–80 Hz.
-
Display: Two-line, 16-character LCD.
-
Installation: Front-panel mounting.
-
Protection Rating: IP42 front / IP21 rear.
-
Operating Temperature: -20°C to +70°C.
-
Humidity: Up to 95%, non-condensing.
Important Configuration Note: The 8444-1019 corresponds to the UMT1 100 V / 5 A A6 package, featuring six analog outputs. Do not assume it has the RS-485 or Profibus options available on other UMT1 packages.
🔧 Daily Maintenance & Care
1. Regular Visual Inspection
-
Inspect the transducer housing for cracks or physical damage.
-
Check the LCD display for missing characters.
-
Inspect electrical terminals for corrosion.
-
Ensure the mounting brackets are secure.
2. Electrical Connection Inspection
-
Verify the 24 VDC auxiliary power supply.
-
Inspect voltage measurement connections.
-
Check current transformer secondary wiring.
-
Ensure that all terminals are properly tightened.
3. Measurement Accuracy Maintenance
-
Compare voltage readings with calibrated instruments.
-
Check current measurement accuracy.
-
Verify frequency readings.
-
Periodically inspect analog output signals.
4. Environmental Maintenance
-
Keep the electrical cabinet clean and dry.
-
Avoid excessive humidity and dust accumulation.
-
Maintain suitable operating temperatures.
-
Prevent excessive vibration and electrical interference.
5. Preventive Maintenance
-
Record measurement readings periodically.
-
Check analog output performance.
-
Maintain calibration and inspection records.
-
Back up configuration parameters where applicable.
🛠️ Troubleshooting & Common Problems
1. Display Does Not Power On
Possible causes:
-
Incorrect auxiliary power supply.
-
Loose power connections.
-
Internal electronic failure.
Solutions:
-
Verify the 24 VDC supply.
-
Inspect power terminals.
-
Check the internal equipment condition through qualified technicians.
2. Incorrect Voltage Measurements
Possible causes:
-
Incorrect voltage wiring.
-
Wrong measurement configuration.
-
Loose terminal connections.
Solutions:
-
Inspect voltage input wiring.
-
Verify the configured measurement system.
-
Compare readings with a calibrated meter.
3. Incorrect Current Measurements
Possible causes:
-
Incorrect CT ratio.
-
Wrong CT polarity.
-
Loose current input connections.
Solutions:
-
Verify the 5 A current input configuration.
-
Inspect CT wiring and polarity.
-
Check the external current transformer.
4. Analog Output Failure
Possible causes:
-
Incorrect output configuration.
-
Damaged output wiring.
-
External monitoring equipment malfunction.
Solutions:
-
Check the selected output range.
-
Inspect analog signal connections.
-
Verify the receiving device input configuration.
5. Abnormal Power Factor or Power Readings
Possible causes:
-
Incorrect phase sequence.
-
Incorrect voltage/current association.
-
CT polarity problems.
-
Incorrect measurement system configuration.
Solutions:
-
Verify phase connections.
-
Check CT polarity.
-
Confirm the configured single-phase or three-phase measurement arrangement.
-
Compare readings with calibrated instruments.
6. Unstable Measurement Values
Possible causes:
-
Electrical interference.
-
Unstable input signals.
-
Loose connections.
-
Incorrect grounding.
Solutions:
-
Inspect signal cables.
-
Check grounding and shielding.
-
Tighten connections after safely isolating the equipment.
-
Verify the stability of external measurement signals.
⚠️ Safety Precautions
-
Disconnect auxiliary power before maintenance.
-
Only qualified electrical personnel should install the transducer.
-
Never open an energized current transformer secondary circuit.
-
Verify voltage and current input ratings before connection.
-
Use appropriate grounding and electrical protection.
-
Do not exceed the specified measurement input limits.
-
Avoid touching exposed terminals.
-
Use calibrated instruments for electrical testing.
-
Do not modify internal circuitry without manufacturer authorization.
-
Confirm all wiring before restoring power.
⭐ Recommended 15 Other Woodward Models
The following models include related UMT1 measuring transducers and Woodward power measurement and control equipment.
| No. | Brand | Model | Product Name |
|---|---|---|---|
| 1 | Woodward | 8444-1002 | UMT1 Measuring Transducer |
| 2 | Woodward | 8444-1022 | UMT1 Measuring Transducer |
| 3 | Woodward | 8444-1027 | UMT1 Measuring Transducer |
| 4 | Woodward | 8444-1043 | UMT1 Measuring Transducer |
| 5 | Woodward | 8444-1009 | UMT1 Measuring Transducer |
| 6 | Woodward | 8444-1057 | UMT1 Measuring Transducer |
| 7 | Woodward | 8444-1084 | UMT1 Measuring Transducer |
| 8 | Woodward | LR 20411 | UMT1 Measuring Transducer |
| 9 | Woodward | LR 21296 | UMT1 Measuring Transducer |
| 10 | Woodward | LR 20949 | UMT1 Measuring Transducer |
| 11 | Woodward | LR 21159 | UMT1 Measuring Transducer |
| 12 | Woodward | 5448-909 | UMT1 Measuring Transducer |
| 13 | Woodward | LR 21035 | MFR1 Multifunction Relay |
| 14 | Woodward | 8444-1090 | MFR300 Multifunction Relay |
| 15 | Woodward | 8440-1946 | LS-5 Circuit Breaker Control |
The UMT1 part numbers above are drawn from Woodward’s product catalogue. Other models are related Woodward power management products, not direct substitutes.
📌 Product Selection Reminder
The Woodward 8444-1019 Rev F UMT1 is designed for electrical measurement applications requiring accurate monitoring of voltage, current, power, and energy parameters.
Important purchasing considerations:
-
Confirm the complete part number: 8444-1019.
-
Verify hardware revision F.
-
Confirm the UMT1 A6 package.
-
Check the 100 VAC voltage input configuration.
-
Confirm the 5 A current input.
-
Verify all six analog output channels.
-
Inspect the LCD display and terminal connections.
The 8444-1019 has an obsolete product status. Woodward lifecycle information indicates that its last-time-buy period and published repair-support period have ended. When sourcing this model, carefully check its condition, testing history, and compatibility with the original electrical system.