| Feature | Specification |
| Model Number | SNT401-53 S1 |
| Manufacturer | Yokogawa |
| Function | Optical Bus Repeater for ESB/Vnet/IP |
| Communication Interface | Fiber Optic (LC Connector) |
| Data Transmission Rate | 128 Mbps (ESB Bus) / 1 Gbps (Vnet/IP) |
| Redundancy | Dual-redundant configuration supported |
| Max Transmission Distance | Up to 15 km (Single-mode fiber) |
| Power Supply | 24V DC Internal Bus Power |
| Operating Temperature | -20°C to +70°C |
| Compliance | SIL3 Capable / CE Mark / ISA G3 Corrosive |
The Yokogawa SNT401-53 S1 serves as a high-reliability optical interface designed to extend the physical reach of the CENTUM VP and CS3000 control system bus networks. By converting electrical signals into optical pulses, this module eliminates electromagnetic interference and provides complete galvanic isolation between remote I/O nodes and the central controller. It is an essential component for distributed architectures in large-scale industrial plants, ensuring seamless data synchronization across vast distances. For specialized procurement and technical availability, you can explore the SNT401-53 S1 within our extensive inventory.
Product Application Fields
- Oil & Gas Refineries: Long-distance connectivity between offshore platforms and onshore control centers.
- Chemical Processing: Reliable data transmission in hazardous areas with high levels of electrical noise.
- Power Generation: Interconnecting distributed turbine control systems and substations.
- Water Treatment: Linking remote pump stations and treatment facilities over wide geographical areas.
Product Q&A
Q1: What is the primary difference between the SNT401 and standard copper repeaters? A1: The SNT401 uses fiber optics, which allows for significantly longer transmission distances (up to 15km) and offers total immunity to lightning strikes and EMI.
Q2: Does the “S1” suffix indicate specific compatibility? A2: The “S1” suffix generally refers to the hardware style or revision level, often indicating enhanced safety standards or specific mounting compatibility within the Yokogawa rack system.
Q3: Can I mix single-mode and multi-mode fiber with this module? A3: No, the SNT401-53 S1 is specifically designed for single-mode fiber to achieve maximum distance and signal integrity; using multi-mode fiber will result in severe signal attenuation.
Recommended Inventory (Other Brands)
- ABB: CI854A 3BSE013210R1 PROFIBUS DP Interface
- Honeywell: TK-PRR021 Redundancy Module
- Siemens: 6ES7155-6AU01-0CN0 (ET 200SP)
- Allen-Bradley: 1756-CN2R ControlNet Bridge
- Bently Nevada: 3500/25 Enhanced Keyphasor Module
- Schneider Electric: BMXNOM0200 Modbus Module
- Emerson DeltaV: VE4001S2T2B5 I/O Interface
- General Electric (GE): IC694MDL660 Input Module
- Foxboro: FBM217 P0914TR Discrete Input
- Triconex: 3008 Main Processor Module
- Woodward: 9907-167 Peak 150 Controller
- Hima: F8627X Communication Module