| Parameter | Details |
|---|---|
| Product Name | Control Unit for Dual-Fuel / Gas Burners |
| Model Number | LEC1/9500 |
| Series | Serie 02 |
| Manufacturer | Siemens (Landis & Gyr) |
| Country of Origin | Germany |
| Mains Voltage | 220V AC – 240V AC (+10% / -15%) |
| Frequency | 50 – 60 Hz |
| Power Consumption | Approx. 5 VA |
| Protection Rating | IP40 |
| Weight | Approx. 1.1 kg |
| Dimensions | 160mm x 105mm x 90mm |
The Siemens LEC1/9500 Serie 02 is a high-performance burner control unit designed for the fully automatic startup and supervision of gas, oil, or dual-fuel burners. It is primarily utilized in large-capacity combustion plants where forced draft burners require precise sequence control and flame monitoring. This “Serie 02” revision incorporates advanced safety logic for pre-purge timing and ignition sequences, working in conjunction with flame detectors (such as the QRA series) to ensure instantaneous fuel shut-off in the event of flame failure or loss of air pressure, adhering to strict international combustion safety standards.
Product Q&A
Q1: What is the primary difference between the LEC1 and standard LAL/LOK burner controls? A1: The LEC1 is a more specialized controller designed for larger, complex dual-fuel systems. It offers more flexible programming for pre-purge times and is often used in industrial applications requiring higher load capacities and specific safety interlock sequences.
Q2: Can this unit be used with a UV flame detector? A2: Yes, the LEC1/9500 is commonly paired with Siemens QRA series UV detectors or ionization probes. The unit processes the signal from these sensors to confirm the presence of a stable flame before and during the fuel release phase.
Q3: What does a red light on the lockout indicator typically signify? A3: A lockout indicates a safety shutdown. This could be caused by a failure to ignite within the safety period, loss of the air pressure signal, or a parasitic light signal detected during the pre-purge phase. The unit must be manually reset after the fault is cleared.
Recommended Stock: 10 Related Brand Models
- Siemens | LAL2.25 Burner Control Box
- Siemens | LMV51.100C2 Linkageless Burner Management System
- Honeywell | RM7800L1087 Relay Module
- ABB | 3BSE018173R1 PM864AK01 Processor Unit
- Bently Nevada | 3500/15 127610-01 Power Supply Module
- Schneider Electric | Modicon BMXP342020 Processor
- Yokogawa | AAI143-S50 Analog Input Module
- Triconex | 3625 Digital Output Module (TMR)
- General Electric (GE) | IS200STCIH2A Termination Board
- Allen-Bradley | 1756-L73 ControlLogix Processor