| Parameter | Details |
|---|---|
| Product Name | Zener Barrier Unit |
| Model Number | BZ-500 |
| Manufacturer | Autronica Fire and Security AS |
| Country of Origin | Norway |
| System Compatibility | AutroSafe / Autroprime Fire Detection Systems |
| Ex Classification | [Ex ia] IIC (Intrinsically Safe) |
| Max Input Voltage (Um) | 250V AC |
| Max Output Voltage (Uo) | 28V DC |
| Max Output Current (Io) | 93 mA |
| Weight | Approx. 0.25 kg |
| Dimensions | 105mm x 90mm x 12.5mm |
| Mounting | 35mm DIN Rail |
The Autronica BZ-500 is an intrinsically safe (IS) Zener barrier specifically designed to interface fire detection loops with sensors located in hazardous (Ex) areas. It functions by limiting the electrical energy—both voltage and current—that can be transferred from the safe-area control panel to the hazardous-area cabling, thereby preventing the ignition of flammable atmospheres. Built to rigorous European ATEX and International IECEx standards, the BZ-500 ensures that even in a dual-fault condition within the control system, the energy levels in the sensing loop remain below the threshold required to trigger an explosion in Zone 0, 1, or 2 environments.
Product Q&A
Q1: What is the primary purpose of the BZ-500 in a fire system? A1: Its primary role is to act as a safety gate. It allows electrical signals to pass between the fire alarm control panel and the detectors in a hazardous area while strictly limiting the energy to levels that cannot cause a spark or thermal ignition.
Q2: Does the BZ-500 require a dedicated earth connection? A2: Yes, Zener barriers like the BZ-500 rely on a high-integrity “IS Earth” (Intrinsic Safety Earth) connection. This connection is vital to divert fault currents safely away from the hazardous area.
Q3: Can any fire detector be connected to the BZ-500? A3: No, only “Intrinsically Safe” (Ex ia or Ex ib) certified detectors should be connected to the hazardous side of the barrier. Using standard non-IS detectors violates the safety certification of the entire loop.
Recommended Stock: 10 Related Brand Models
- Autronica | BWA-100 Socket Base for Detectors
- Autronica | BD-501/N Heat Detector (Ex ia)
- ABB | 3BSE018173R1 PM864AK01 Processor Unit
- Honeywell | CC-PAIH02 High Level Analog Input
- Bently Nevada | 3500/33 149986-01 16-Channel Relay Module
- Siemens | 6ES7134-4GB11-0AB0 Analog Input Module
- Schneider Electric | Modicon BMXP342020 Processor
- Triconex | 3625 Digital Output Module (TMR)
- Yokogawa | AAI143-S50 Analog Input Module
- Allen-Bradley | 1756-IF16 ControlLogix Analog Input