The ABB / Bailey Infi 90 IMASI13 (Analog Slave Input Module) is a high-density, microprocessor-based input module designed for the Bailey Infi 90 and NETWORK 90 distributed control systems (DCS). It is engineered to interface high-level analog process signals (such as 4–20 mA current loops or voltage inputs) directly into the control system network, converting field data into digital format for real-time monitoring and control loops.
Technical Parameters Table
| Parameter | Specification |
| Product Name | ABB / Bailey Infi 90 IMASI13 Analog Slave Input Module |
| Manufacturer | ABB / Bailey (Infi 90 / Net 90 Distributed Control System) |
| Module Type | Analog Slave Input Module (IMASI) |
| Input Channels | Multi-channel high-level analog inputs (supports current and voltage signal ranges) |
| System Bus Interface | Infi 90 Plant Loop communication via bus interface module or termination units |
| Power Requirements | Powered via Infi 90 rack backplane (+5V DC logic power and local distribution rails) |
| Operating Temperature | 0^\circC to +70^\circC (+32^\circF to +158^\circF) |
| Storage Temperature | -40^\circC to +85^\circC (-40^\circF to +185^\circF) |
| Mounting Configuration | Plugs into standard Infi 90 module mounting units (MMU) / rack chassis |
| Certificate of Origin (COO) | Available upon request |
| Certificate of Conformance (COC) | Available upon request |
⚙️ Operational Architecture & Modes
- Automatic Scanning Mode: The module operates autonomously, continuously multiplexing, digitizing, and scaling analog input channels before publishing the processed values to the Infi 90 communication loop.
- Slave Processing Architecture: As a slave module, it responds to configuration and data requests initiated by higher-level master modules (such as Multi-Function Processors – MFP) across the system highway.
- Onboard Diagnostics: Built-in hardware watchdog circuits and diagnostic routines continuously monitor internal power rails, analog-to-digital (A/D) conversion accuracy, and communication health.
🛑 Fault Diagnostics & System Integration
- Fault Reporting: Detects open-loop conditions, out-of-range inputs, and internal hardware faults, instantly flagging error states to the control processor via system status registers.
- Fail-Safe Handling: When a channel fault or communication drop is identified, control strategy blocks in the master controller can be configured to substitute default safe values or hold the last known good value.
- System Recovery: Restoring normal operation after a module trip or replacement involves clearing field wiring discrepancies, verifying rack seating, and re-initializing the configuration via the engineering workstation.
📐 Mechanical Installation Requirements
- Mounting Method: Designed for vertical insertion into a standard Bailey Infi 90 Module Mounting Unit (MMU) rack slot, locking securely into backplane edge connectors.
- Clearance Space: Ensure a minimum of 50 mm of clear vertical space above and below the module rack chassis to allow proper convective airflow and cable routing.
- Thermal Management: Relies on natural air convection; maintain switchgear enclosure internal ambient temperatures strictly within the 0^\circC to +70^\circC operating range.
🔌 Electrical Wiring Guidelines
- Terminal Definitions: Field analog signals terminate at dedicated Termination Units (TU) or swing-arm termination assemblies mounted at the rear of the cabinet, which route signals to the front module via pre-engineered cable harnesses.
- Wire Size Requirements: Use shielded twisted-pair instrumentation copper conductors (typically 0.5 to 1.5 mm^2 / 20 to 16 AWG) to minimize electrical noise interference.
- Grounding Specifications: Shield drain wires must be securely grounded at the cabinet’s instrument earth ground bus, and the module chassis must maintain a low-impedance bond to the main cabinet framework.
❓ Frequently Asked Questions (Q&A)
- Q: What is the primary function of the IMASI13 module?
- A: It acts as an analog input acquisition card for Infi 90 systems, converting field-level 4–20 mA or voltage signals into digital data for use by system controllers.
- Q: Can the IMASI13 be replaced while the system is powered on?
- A: Maintenance and replacement protocols depend on the specific hardware revision and system redundancy configuration; always follow standard Infi 90 safety guidelines and pull power/signal blocks where specified before extraction.
- Q: What system controllers are compatible with the IMASI13?
- A: It is designed to work within standard Infi 90 and NETWORK 90 architectures alongside Multi-Function Processors (MFPs) and classic communication loop setups.
🔍 Recommended Alternative Series and Models
- ABB / Bailey IMDSV01 Digital Slave Input Module
- ABB / Bailey IMASI03 Analog Slave Input Module (Legacy variant)
- ABB / Bailey IMMFP02 / IMMFP03 Multi-Function Processor Modules
- ABB Symphony Melody I/O Modules
- Emerson / Fisher Provox Analog Input Cards