135613-02 Standalone I/O Processor

135613-02

Technical Parameters:

  • User defined tag-based programming for descriptive I/O naming
  • Simple-to-use instructions and Easy math to eliminate complex ladder logic rungs
  • Application tools for quick access to setup, programming, debugging and PAC control
  • Task Manager for quick and easy prioritization of Ladder Logic code
Categories: ,
Get a quote, please contact me immediately:
Simon Zhang
dcsplcsales@gmail.com
Phone/Whatsapp/Skype/Wechat: +86 133 6590 9307

Description

135613-02 Standalone I/O Processor


The 135613-02 provides many dedicated modules and function modules for various signals and applications in the industrial field, such as temperature, tension, stepper motor drives, oscilloscopes, drum sequence generator signals, incremental pulse coding signals, weighing and ultrasonic signals, power measurement and grid synchronisation, PWM outputs, etc. The 135613-02 is a powerful and powerful I/O processor that can be used for a wide variety of applications. They make it very easy to connect various forms of field signals into a digital control system with PCC at its core.

Inside the 135613-02 module, the CPU’s data bus is separated from the I/O bus and is configured with an independent I/O processor. The main CPU contains an independent time processing unit TPU (Time Processing Unit ), which handles simple or complex timing tasks at high speed without increasing the CPU load, and its reference timing frequency can be as high as 6.29MHz

The 135613-02 uses a single-task clock scanning or monitoring programme (except for certain high-grade PLCs, such as Siemens’ S7-300/400 series, Rockwell’s ControlLogix series, etc.) to handle the logic operation instructions of the programme itself and the status acquisition and refreshment of external I/O channels, with the entire application contained in a single loop cycle.