FOXBORO AB7000-C Field Output Contactor

AB7000-C

If you need to inquire or purchase ,please send the product models to my email or call me directly .

Contact detail:

Xiamen Xiongba E-commerce Co., Ltd

Mobile/ WeChat/ WhatsApp:+86-133 6590 9307

E-mail: geabbamy@gmail.com

Contact: Simon Zhang

Website: https://www.dcsplcsystem.com

Address: Unit 2008, Chuangxiang Center, No. 1733, Luling Road, Siming District, Xiamen, Fujian

Categories: ,
Get a quote, please contact me immediately:
Simon Zhang
dcsplcsales@gmail.com
Phone/Whatsapp/Skype/Wechat: +86 133 6590 9307

Description

AB7000-C Field Output Contactor


AB7000-C control includes normal belt control and forward and reverse belt control, the principle is similar, the equipment automatic start conditions are available, the automatic state of the press start button (or the conditions of the smooth start), the first output bell signal, issued by the start alarm, and at the same time began to time, 3 seconds after the issuance of the belt start command output to the field contactor, so that the action of the motor to start, and at the same time, return to the equipment running signal, together with the start output command for the DO output Start output command together with self-hold for DO output. When the stop button is pressed, the automatic start circuit is disconnected, there is no output from DO, the contactor is disconnected and the equipment stops.

AB7000-C equipment manual start conditions are available, manual state, press the manual start button, the manual start circuit is turned on, the belt start output command is issued to the field contactor, the contactor action, start the motor, and at the same time return to the equipment running signal, together with the start output command for the DO output to do self-maintaining. When the manual stop button is pressed, the manual start circuit is disconnected, there is no output from DO, the contactor is disconnected and the equipment stops.

The AB7000-C’s selected material line equipment operates normally. If one of the equipment in the material line stops (malfunction or non-fault stop), the equipment upstream of this equipment in the selected material line will be interlocked to stop, and the equipment downstream will remain in operation. For example, if the selected material line is A1→A2→A3→A4→A5→A6 are in the running state, when A5 has a fault stop, its upstream equipment A1→A2→A3→A4 will stop, while the downstream equipment A6 is still in the running state. Since the control of the material field is a process of smooth control, this can avoid the occurrence of pile of materials due to the intermediate equipment failure and shutdown, and effectively reduce the economic losses.