PFSK152 3BSE018877R1 Embedded Output Power Supply

PFSK152 3BSE018877R1

If you need to inquire or purchase ,please send the product models to my email or call me directly .

Contact detail:

Xiamen Xiongba E-commerce Co., Ltd

Mobile/ WeChat/ WhatsApp:+86-133 6590 9307

E-mail: geabbamy@gmail.com

Contact: Simon Zhang

Website: https://www.dcsplcsystem.com

Address: Unit 2008, Chuangxiang Center, No. 1733, Luling Road, Siming District, Xiamen, Fujian

Categories: ,
Get a quote, please contact me immediately:
Simon Zhang
dcsplcsales@gmail.com
Phone/Whatsapp/Skype/Wechat: +86 133 6590 9307

Description

PFSK152 3BSE018877R1 Embedded Output Power Supply


PFSK152 3BSE018877R1 relay output: the advantage is that different common points can be with different AC and DC loads, and the voltage can be different, with a load current of up to 2A points; but the relay output mode is not applicable to high-frequency action of the load, which is determined by the life expectancy of the relay (2) Thyristor output: with a load capacity of 0.2A / point, can only be with AC loads, can be adapted to High-frequency operation, response time of 1ms (3) Transistor output: the biggest advantage is that it is suitable for high-frequency operation.

PFSK152 3BSE018877R1 output with inductive loads, load power failure will cause surge current impact on the PLC output, for this reason, DC inductive loads should be connected next to the DC inductive diode, AC inductive loads should be connected to the surge absorber circuit, which can effectively protect the PLC When the output of the two physical quantities in the PLC has been carried out inside the software interlocks, the outside of PLC should be interlocked to strengthen the system. When two physical outputs have been software interlocked inside the PLC, they should be interlocked outside the PLC as well to strengthen the reliability of the system.

The number of COM points of PFSK152 3BSE018877R1 is not the same, some have one COM point with 8 output points, some have 4 output points, and some have 2 or 1 output point When there are many kinds of loads and the current is large, use a PLC product with one COM point with 1-2 output points; when the number of loads is large and the number of kinds is small, use a PLC product with one COM point with 4-8 output points. When there are many kinds of loads and the current is large, use one COM point with 1-2 output points; when the number of loads is large but the number of kinds is small, use one COM point with 4-8 output points, which will bring a lot of convenience to the circuit design. Add a fuse to each COM point, 2A fuse for 1-2 outputs, and 5-10A fuse for 4-8 outputs.