UAD206A101 3BHE019958R0101 Highly Reliable I/O Module

UAD206A101 3BHE019958R0101

Technical Parameters

D2-04TD1 – 4 pt. 12-24 VDC current sinking output module, 1 common (4 common terminals),4.0A/point, 8.0A/module, fused per point (non-replaceable), removable terminal

Categories: ,
Get a quote, please contact me immediately:
Simon Zhang
dcsplcsales@gmail.com
Phone/Whatsapp/Skype/Wechat: +86 133 6590 9307

Description

UAD206A101 3BHE019958R0101 Highly Reliable I/O Module


UAD206A101 3BHE019958R0101 Combined with its own long-term scientific research and technological innovation accumulation and its rich experience in engineering applications, through innovative breakthroughs, continuous improvement, through the examination, the formation of a new generation of high-quality and stable, advanced and practical, friendly and open master control system – UW500 (UWinPAS500). UWinPAS500) centralised control system. It has been widely used in chemical, pharmaceutical, oil refining, petrochemical, iron and steel, energy, building materials, light industry, paper making, environmental protection and other industries. It has the features of high reliability, open system, powerful function and easy maintenance.

UAD206A101 3BHE019958R0101 Hardware redundancy design: power supply module hot standby redundancy, support for dual grid input, and over-voltage, over-current protection; control network and system network are dual redundancy; control module dual redundancy, zero switching time, to ensure control continuity; the system has built-in all the switching and analogue input voting algorithm, output voting algorithm, input and output self-test and fault detection. The system has built-in all switching and analogue input voting algorithms, output voting algorithms, input/output self-test and fault reporting mechanism, which do not require user programming, and the redundancy design can be achieved automatically by configuration;

UAD206A101 3BHE019958R0101 Highly reliable I/O modules: point-to-point isolation, point-to-point mutual isolation, point-to-point power distribution, online point-to-point replacement, which can meet the requirements of nuclear power, emergency stop and other high-reliability and high-security areas; Component Intelligent Design: the I/O modules, I/O modules, control modules, and communication modules are all configured with microprocessors or multi-processors, which support the module self-diagnosis, Fault isolation, online plugging, online maintenance; control station size: analogue input and output AIO: 512, or digital input and output DIO: 1024; the system supports 32 control stations, then the system size: AIO: 16384, or DIO: 32768.